Power Generators12.5kva 1ph Silent Diesel Generator With ATS Heavy Duty Premier
Product details
🔋 12.5kVA 1-Phase Silent Diesel Generator
⚡ Power Output: 12.5kVA (10kW) – Reliable backup power for homes and businesses.
🚜 Engine Type: 4-stroke diesel – Water-cooled generator, direct-injection engine for efficiency and durability.
🔋 Voltage: 230V AC – Single-phase stable power supply for essential electrical appliances.
⛽ Fuel Capacity: 30-50L – Large tank ensures extended operation with minimal refueling.
🔇 Noise Level: ≤65dB(A) – Ultra-quiet performance for residential and commercial environments.
🖥️ ATS Functionality: Automatic switching – Seamlessly transitions power during outages for convenience.
🔋 12.5kVA 1-Phase Silent Diesel Generator with ATS – Heavy Duty Premier ⚡
🔍 Overview
The 12.5kVA 1-Phase Silent Diesel Generator with ATS (Automatic Transfer Switch) - Heavy Duty Premier is a high-performance backup power solution designed for both residential and commercial applications. It is built for durability 🏗️, fuel efficiency ⛽, and quiet operation 🔇, making it ideal for environments where noise reduction is essential.
⚙️ Technical Specifications
🛠️ Engine & Performance:
- 🔌 Power Output: 12.5kVA (10kW)
- 🔄 Phase: Single Phase
- 🚜 Engine Type: 4-stroke, water-cooled, direct-injection diesel engine
- 📏 Displacement: Approximately 1.5L (varies by manufacturer)
- ⚡ Rated Speed: 1500 RPM / 3000 RPM (depending on model)
- ⛽ Fuel Type: Diesel
- 🛢️ Fuel Tank Capacity: 30-50 liters (approximate, varies by model)
- ⚙️ Fuel Consumption: ~2.5L per hour at 75% load
- 🌊 Cooling System: Water-cooled radiator system
- 🔑 Starting System: Electric start with battery
- 🔇 Noise Level: ≤65 dB(A) at 7 meters
⚡ Alternator & Electrical System:
- 🔋 Voltage: 230V AC (Single Phase)
- 🔄 Frequency: 50Hz / 60Hz (depending on configuration)
- 🔣 Power Factor: 1.0 (Single Phase)
- 🛡️ Voltage Regulation: AVR (Automatic Voltage Regulator)
- 🔧 Insulation Class: H Class
🖥️ Automatic Transfer Switch (ATS):
- ⚙️ ATS Functionality: Automatically detects power failure and switches between main power and generator supply
- ⏳ Response Time: Fast switching within seconds of power failure
- 📊 Control Panel: Digital controller with LCD/LED display for voltage, frequency, and engine monitoring
- 🛑 Protection Features: Overload protection, low oil pressure shutdown, high temperature shutdown, short-circuit protection
🏗️ Physical & Structural Details:
- 🛠️ Canopy Type: Soundproof, weather-resistant, and corrosion-resistant enclosure
- 🔩 Frame: Heavy-duty steel frame with vibration-dampening mounts
- 📏 Dimensions (L×W×H): Approx. 1500mm × 800mm × 1000mm (varies by brand)
- ⚖️ Weight: 350-450 kg (approximate)
- 💨 Exhaust System: Low-emission muffler for reduced noise and fumes
🏡 Applications
The 12.5kVA Silent Diesel Generator with ATS is ideal for various applications, including:
✔ 🏠 Residential Backup Power: Ensures uninterrupted power supply during outages.
✔ 🏢 Small Businesses & Offices: Powers essential equipment such as computers, lights, and security systems.
✔ 🛒 Retail & Commercial Spaces: Supports refrigerators, POS systems, and communication devices.
✔ 🏥 Healthcare & Clinics: Provides reliable power for medical equipment and lighting.
✔ 🚜 Agriculture & Farms: Runs irrigation pumps, lighting, and farm machinery.
✔ 🏗️ Construction Sites: Powers tools, lighting, and temporary site offices.
✔ 🎉 Outdoor Events: Provides silent and efficient power for lighting, sound systems, and catering setups.
🛠️ Maintenance & Service
Regular maintenance ensures optimal performance and longevity of the generator. Below are key maintenance activities:
🗓️ Daily Checks:
- ✅ Inspect fuel and oil levels before operation.
- ✅ Check for any leaks or loose connections.
- ✅ Ensure the battery is charged and terminals are clean.
🔄 Periodic Maintenance (Every 50-100 Hours):
- 🔄 Change engine oil and oil filter.
- 🔄 Clean or replace the air filter.
- 🔄 Check and tighten bolts, nuts, and fittings.
🛠️ Quarterly Maintenance (Every 200-250 Hours):
- 🛠️ Replace fuel filters and coolant if necessary.
- 🛠️ Inspect belts and hoses for wear and tear.
- 🛠️ Check the alternator and electrical connections.
🛢️ Annual Maintenance (Every 500-1000 Hours):
- 🔧 Perform a complete engine overhaul if required.
- 🔧 Test the ATS functionality and recalibrate voltage settings.
- 🔧 Check exhaust system and muffler for clogging or damage.
By following this maintenance schedule 📅, the generator will operate efficiently and reliably for many years.
The 12.5kVA 1-Phase Silent Diesel Generator with ATS – Heavy Duty Premier is a robust 🏗️, fuel-efficient ⛽, and low-noise 🔇 power backup solution suitable for various industries. With its automatic power switching ⚡, durable engine 🛠️, and soundproof design 🔕, it provides uninterrupted electricity with minimal maintenance requirements.
Whether for residential 🏡, commercial 🏢, or industrial 🏭 use, this generator ensures a stable power supply even during extended outages. 🔋⚡
Delivery & collection
We arrange delivery across Kenya. Delivery charges and timelines depend on your location and the size of the equipment. Prefer to collect? Visit Ruevan at Mithoo Biashara Center, Moi Avenue, Nairobi.
Delivery policyNeed help choosing?
Not sure whether this product suits your needs? Our team will help you check the right size, capacity and compatibility. Call or WhatsApp +254 757 191145 for help choosing your equipment.
Not sure what you need?
Tell us what you want to power, pump or clean. We’ll help you choose.








